Daewoo DTB Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Téléviseurs et moniteurs Daewoo DTB Series. Service Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 21
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
Service Manual
Split System Air
Conditioner
Model: DTB-F071LH-DVI
DTB-F091LH-DVI
DTB-F121LH-DVI
DTB-F181LH-DVI
DMB-F2713LH-AVO
DAEWOO ELECTRONICS CO., LTD.
by Nemko
S/M NO. : DTBF071001
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1 - Service Manual

1Service ManualSplit System AirConditionerModel: DTB-F071LH-DVIDTB-F091LH-DVIDTB-F121LH-DVIDTB-F181LH-DVIDMB-F2713LH-AVODAEWOO ELECTRONICS CO., LTD.by

Page 2

4.Indoor unit combination: Caution on combination The one-drive-four outdoor unit M4OA-27HRIN1 nominal cooling capacity is 8kw(under condition of ambi

Page 3 - 1. Features:

5. Capacity table M4OA-27HRIN1 (7k+7k+7k+7k) COOLING OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC Total capacity k

Page 4 - 2.Specification

6. WIRING DIAGRAM Indoor unit:

Page 5

Outdoor unit (M4OA-27HRIN1)

Page 6

7. Electric control functions: 7.1 Protection 1. 3 minutes delay at restart for compressor. 2. Temperature protection of compressor top, compres

Page 7 - Electronic control

7.2.2 Dehumidifying mode 1.The indoor fan is fixed in low speed 2. Low room temperature protection: When room temperature decreases to below 10℃, indo

Page 8

If one of following conditions is satisfied, end the defrost and turn into heating mode: a. The defrost time has reached to 10 minutes. b. When the te

Page 9 - 3.Outline and dimension

1. The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes. 2. Timer on: first turn off the A/C, the A/C will be aut

Page 10 - 4.Indoor unit combination:

7.9 Outdoor unit LED display function: 1. When stand-by it display number of indoor unit online; 2. When operation it display frequency of outdoor u

Page 11 - Conditions

2. Fan state: Display Corresponding mode 0 Off 1 Low fan 2 High fan 3. Opening degree of EXV: Opening degree equals the display data times 8; 4.

Page 12 - Indoor unit:

CONTENTS 1. Features 2. Specification 3. Outline and dimension 4. Indoor unit combination 5. Capacity table 6. Wiring diagram 7. Electronic control

Page 14 - 7.2 Operating mode

DAEWOO ELECTRONICS CO., LTD686, AHYEON-DONG MAPOGU,SEOUL, KOREA.C.P.O. BOX 8003 SEOUL KOREATELEX: DWELEC K28177-8CABLE: "DAEWOOELEC"FAX: +82

Page 15

1. Features: 1) Fashion design, quality life; 2) Low operation noise; 3) High efficiency screw fan; 4) Equal, fast, wide-angle cooling, more comfo

Page 16 - 7.4 Manual switch

2.Specification indoor unit Model MSQ4I-07HRIN1 MSQ4I-09HRIN1 MSQ4I-12HRIN1 MSQ4I-18HRIN1 Power supply Ph-V-Hz 1Ph,220-240V~,50Hz 1Ph,220-240V~,50

Page 17 - 7.6 Auto restart function

Dimension (W*H*D) mm 650x30x650 650x30x650 650x30x650 650x30x650 Packing (W*H*D) mm 715x115x715 715x115x715 715x115x715 715x115x715 Indoor unit(pa

Page 18 - 7.10 Check function:

OUTDOOR UNIT: Outdoor Model M4OA-27HRIN1 Indoor unit combination single double Treble Quadplex Power supply Ph-V-Hz1Ph,220-240V~,50Hz Cooling Capaci

Page 19 - 7.12 Oil return function

a.Number of rows 2 b.Tube pitch(a)x row pitch(b) mm 25.4×22 c.Fin spacing mm 1.5 d.Fin type (code) Hydrophilic aluminium e.Tube outside dia.a

Page 20 - 8. Exploded View

Outdoor temp: 35°CDB; Equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CD

Page 21 - DAEWOO ELECTRONICS CO., LTD

3.Outline and dimension Indoor unit(7k/9k/12k/18k): 580(Body)67600(Ceiling hole)650(Panel)401(Hook-location)611(Hook-location)580(Body)422 28.5600(Cei

Commentaires sur ces manuels

Pas de commentaire