HÖRMANN
Spindle drive operator for hinged gates Installation Instructions
DSA 100
DSA 100 L
DSA 200
DSA 200L
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - DSA 200L

page 1HÖRMANNSpindle drive operator for hinged gates Installation InstructionsDSA 100DSA 100 LDSA 200DSA 200L

Page 2

page 10Overview of two-wing version4bA Stop plate "close" (on site)B Gate wingC PostD Spindle drive operatorE Control unitF Gate contact &qu

Page 3

page 114cFixing the pivot points"Standard" version"Long" versionA12B* Distance „c“ for LH hinging (drive operator on left gate win

Page 4

page 12Post mounting bracketIn order to ensure an opening angle of 90 degrees, the addition of measurements a + b should roughly correspond to thespin

Page 5

page 13Release box (for single-wing version, this may have to be reversed, depending on which side the gate is hinged)180°reversedL=b+c+10 (table 1, p

Page 6

page 145Overview of cable layout5aSingle-wing gate systemSecure the control unit to the post using wall plugs and screws, then plug into mains and mak

Page 7

page 156Overview of control unit D 200; single- and two-wing versionsA IndicatorB LEDC Power limit "open"D Power limit "close"E Te

Page 8

page 167Circuit diagram D 200Factory-bridged terminals, coding switchDescription Terminal block Bridged Codingterminals switch"Stop" button

Page 9

page 178Electronic aerial IP 65Plug electronic aerial into the control unit (socket ST2) as shown in fig. 6, point "S".The range may vary wi

Page 10

page 18Adjustment and codingThe power limits are now set.Putting into operationSwitch on at the mains. LED lights up. After pressing the test bu

Page 11 - Fixing the pivot points

page 199dCoding the receiver for single-wing version (only with electronic aerial)Press button "P" for 2 seconds"F" is indicatorLE

Page 12 - Post mounting bracket

page 21EBCDA Spindle drive operatorB Pivot - postC Pivot - gate wing, "open" positionD Pivot - gate wing, "closed" positionE Motor

Page 13 - L=b+c+10 (table 1, page 2)

page 209eProgramming the receiver for two-wing version (only with electronic aerial)Press button "P" for 2 seconds"F" is indicator

Page 14

page 219fProgramming the receiver for the two-wing version - gate 1 only(only with multi-channel hand transmitter, e.g. button "B" with two-

Page 15

page 22Press the button and keep it depressed until the gate has reached the final "close" position.Fine adjustment can be made by brief

Page 16 - only with 2-wing version

page 239hSetting the limit stops for the two-wing version - gate 1 (gate must be in "open" position)Press button "P"Press button &

Page 17 - Electronic aerial IP 65

page 249iSetting the limit stop for the two-wing version - gate 2Press button "P"Press button "P"Press button "P""I

Page 18 - The power limits are now set

page 25Setting the time-delayed start for the two-wing version9jTo program the time-delayed start, press button .The set value is indicator. By

Page 19 - Programming is completed

page 269k9lIndicator 7 to 8:Setting the "prewarning" or "gate open time" in accordancewithfig. 9n.Connection of red traffic light

Page 20

page 27Indicator Open time Prewarningtime0 5 sek. 2 sek.1 10 sek. 4 sek.2 15 sek. 6 sek.3 20 sek. 8 sek.4 25 sek. 10 sek.5 30 sek. 12 sek.6 35 sek. 14

Page 21

page 28Disengaging the drive operator in the event of a power failure10ABCDa) Release from the insideTurn rotary latch (B) around 90°. The release box

Page 22

page 29 100 128 5 10 5EBAAB C D1111aElectr. lock on single-wing hinged gate (electr. gate post lock, code no. 562 917, required)Fitting the elect

Page 23

page 32Overview of spindle drive operator for hinged gatesVoltage: 220 - 240 V, 50 HzCurrent input: 1 A max.Power input: 0.24 kW max.Temperature toler

Page 24

page 30Test Instructions (only for the specialist!)Trouble shootingFault Cause RemedyNo green light No voltage. Check mains supply.on operation Check

Page 25

page 43a3Overview of single-wing versionHörmann aluminium hinged gate systemA Stop plate with lockB Gate wingC Gate postD Spindle drive operatorE Cont

Page 26 - Cancelling the settings

page 5A Stop plates with lockB Gate wingC Gate postD Spindle drive operatorE Control unitF Gate contact "open" (on site)3bOverview of double

Page 27

page 63cOverview of post construction, rectangular profile 120 x 60Overview of post construction, rectangular profile 120x60 or 120x1203e3dOverview of

Page 28

page 73fFitting the mounting bracketAs shown in fig. 3f, screw post mounting bracket (A) and angle piece (B) together with the counterplate (C),pre-fi

Page 29

page 8The distances between the gate pivot point and the drive operator pivot point are determined by the spindlestroke of 300 mm, which can be used f

Page 30 - Fault Cause Remedy

page 94a4General hinged gate systems, retrofitting of Electr. drive operatorOverview of single-gate versionA Stop plate "close" (on site)B G