Daewoo DWC-ED1232 Manuel de service Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
19
4) Detection of Overflow
1 The water level is measured every two minutes after the initial water supply to drain water if the level is
above the overflow level.
2 If the water level is measured above the overflow level three times, the 'E3' error is displayed and the wash
cycle is suspended. However, the water continues to be drained.
3 If the water level is first measured to be above the overflow level during the "Baby Care" program, the
heating cycle is skipped. The 'E3' error is displayed on the third occurrence of overflow detection, and the
wash cycle is suspended. However, the water continues to be drained.
4 If the water level is measured to be above the overflow level when the wash cycle is suspended, the 'E2'
error takes place but the water continues to be drained.
5) Water Level for Heating Cycle
1 If the water level is measured below the preset level, the heater is turned off to prevent overheating or short
circuit during the heating cycle.
Vue de la page 19