Daewoo RFS-26D1 Series Guide d'installation Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 67
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
19
Compensation of R-sensor ON/OFF temp. (down)
In case temperature of refrigerator compartment is weak or insufficient,
take the following action.
INPUT CONTROL OBJECT
CONTENTS REMARKS
Main PCB
Resistance of R-sensor
ON/OFF Temp. of Refrigerator
R42 : R-SENSOR standard resistance in normal mode (31.4)
In case of weak ref.
1) Cut J1 to increase the standard resistance by 2㏀⇒3 down
2) Cut J1 & J2 to increase the standard resistance by 4㏀⇒6 down
4-11. Compensation of R-sensor ON/OFF Temp.
R-SENSOR
J2
R42
(31.4)
R43
(2)
R44
(4)
J1
J1 - cut - cut
J2 - - cut cut
Temperature
compensation
0
-3
0
-6
Resistance
R42 R42+R43 R42 R42+R43+R44
31.4
(31.4+2)
31.4
(31.4+2+4)