Daewoo RFS-26D1 Series Guide d'installation Page 52

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 67
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 51
51
Troubleshooting of Evaporator Sound
1. Hiss Sound from Capillary Tube
1) “I” tube is used to connect the
capillary tube and evaporator.
(2 welding points : , )
2. Shaking or trembling Sound of Evaporator
2) When such a sound is made,
attach a absorber on the tube
including 2 welding points.
1) Check whether evaporator is fastened tight
with the screws of 5 points.
“I” tube
1
2
Vue de la page 51